The significance of supervised monitoring modules utilized in management and monitoring of extinguishing methods

In many places from chemistry laboratories to industrial facilities, in order to ensure the security of life and property against a attainable fire hazard, extinguishing systems are used in addition to detection and alarm systems. It can be extremely important that the extinguishing techniques installed can be triggered by the fireplace extinguishing control panel, in order to get rid of a possible hearth with early intervention.
In order to satisfy these needs, and with 35 years of sectoral data and experience, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel working based on the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant efficiency of the indicators and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be began manually and remotely; and
to guarantee that the extinguishing course of can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced utilizing surface-mount technology and are aimed at making the automation of the extinguishing system and fire and gasoline detection system excellent.
เกจวัดแรงดันไฮดรอลิค : Mavili
Mavili Elektronik develops its merchandise by all the time contemplating the wants of the set up. In instances that require the combination of the extinguishing system with the clever addressable fire detection system, it supplies options through the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an important position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or short circuit in the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with doubtlessly crucial consequences. For this purpose, when selecting monitoring modules, it must be taken under consideration that they’ve supervised features.
Image copyright: Mavili
Since Maxlogic intelligent addressable fireplace detection and alarm management panels are continuously speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch situations corresponding to open circuits and brief circuits that may happen within the system. Many tasks may be carried out within the hearth extinguishing installation, such because the control and monitoring of all valves that can interrupt the circulate of water, water circulate alarm switches, pressure swap, and electric or diesel hearth pumps.
By including two contact monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be used to regulate errors and the opposite to regulate the hearth state of affairs, monitoring and control of the extinguishing system by way of an intelligent addressable hearth detection and alarm system can be performed effectively.
For extra information, go to www.mavili.com.tr/en