What is the leading ignition protection type for UHP pressure transducers?

The leading ignition protection type is crucial for the electrical connection of a pressure sensor with explosion protection. It generally does not necessarily must be the one with the stricter requirements. This applies, for example, for the UHP pressure transducers of the WU series from WIKA. They are designed for used in semiconductor production.
Explosion protection can be an indispensable safety precaution there. It is because the substances necessary for manufacturing include highly flammable gases. Consequently, there is a risk of an explosive atmosphere forming.
Explosion protection concept
UHP pressure transducers for such processes should be made with the corresponding safety. Besides their small design and specific process connections, the models WUC-1x and WU-2x have a thorough explosion protection concept. The marking of the instruments provides information on this:
II 3G Ex ec ic IIC T6/T5/T4 Gc X
The abbreviations listed in them mean, in more detail:
II 3G:
Equipment group 2 (every area except mining), can be utilized in zone 2 (rare and short-term Ex atmosphere).
Ex ec ic:
Ignition protection types ?ec? (increased safety) and ?ic? (intrinsically safe; zone 2).
?Ex ec? has replaced the ignition protection type ?Ex nA? (non-sparking) since the start of 2022. However, this does not affect the Ex concept of the instruments.
IIC:
Explosion group (here: gases, resistive ignition energy of 40 �J, ideal for hydrogen/acetylene).
T6/T5/T4:
Temperature classes. T6 as the highest requirement means a maximum permissible surface temperature in the Ex environment < 85 �C (max. surface temperature of the WUC-1x and WU-2x: 40 �C).
Gc:
?Equipment Protection Level? (EPL) for zone 2 per IEC 60079-0
X:
Specific requirements which are listed in the operating instructions (for example, the suitable mating connector).
?ec? is the leading ignition protection type
It really is noticeable that the marking contains two ignition protection types. However, only 1 is pertinent for the electrical connection: the leading ignition protection type. Regarding ไดอะแฟรม ซีล from the WU series, it is the Ex ec (Ex nA around 2022) mentioned first and not the stricter Ex ic. This can also be seen in the bond values in the data sheet and operating instructions. Only the specification of the maximum supply voltage UN = 30 V, that is also stated in the IECEx certificate, is relevant here.
What does the classification ?Ex ic? are a symbol of? It only applies to the potentiometer of the transducer. The resistive component has an intrinsically safe circuit and can therefore be adjusted to improve zero drift during operation. Within their overall form, the WU models do not require an intrinsically safe circuit. However, เกจวัดแรงดัน must never be disconnected from the circuit during operation or when an Ex atmosphere is present.
Note
More info on the WUC-1x and WU-2x UHP pressure transducers and on the subject of hydrogen are available on the WIKA website. In case you have any questions, your contact will gladly assist you to.