Pressure transmitters and pressure gauge s could be adapted to nearly every process condition using valves, protective devices and/or fittings. WIKA offers such combinations by means of a ?hook-up?, an application-specific and ready-to-install solution. It eliminates all the disadvantages that users experience with the choice of doing the assembly themselves.
1. The logistical effort:
This is considerable. Measuring instruments, valves along with other accessories, if they are brought together in-house, usually have to be sourced from different manufacturers, frequently from more than two companies. The order processes should be coordinated, that may be time-consuming. Furthermore, supplier management requires additional resources.
2. Compatibility problems (risk of leakage):
Combinations of pressure measuring instruments with instrumentation valves and accessories are not standard solutions. Both components of this assembly generally come, as mentioned, from different manufacturers. This increases the probability of complications during assembly.
The difference in these measuring arrangements with differential pressure gauges is obvious ? on the left, an example of an assembly made by the operator themselves, on the proper, the hook-up solution from WIKA.
An example of this, shown here, is the mix of a differential pressure gauge with a valve manifold. The bond of the measuring instrument includes a different centre distance than that of the selected valve manifold (picture left). When this happens, the connection may be accomplished through an assembly with two pipe pieces and four adapters. But this solution escalates the outlay in time and expense, and also the threat of leakage, by doubling the sealing points (see arrow marks). Difficulties in assembly also arise if the tolerances of the connection interfaces from different suppliers usually do not match exactly. This also carries the chance of leakage. In order to achieve the required compatibility, the qualification and delivery specification should be defined for every supplier with considerable effort.
Two types of hook-up solutions:
Left: Pressure gauge with overpressure protector, a valve to split up the measuring instrument from the process and a siphon tube that protects the entire measuring arrangement from excessive temperatures.
Right: Pressure gauge with overpressure protector and monoflange (this enables separation of measuring instrument and process in the case of flange connections).
3. The installation effort:
On top of the requirements for the procurement of suitable components, are the assembly costs for measuring points with instrumentation valves and accessories also added. These add the development of special know-how and employee training to the provision of a suitable workplace, including tools and the necessary materials. Furthermore, a quality control is mandatory to check on the functionality and reliability of the measuring arrangement, especially its leak tightness. That is especially important if, for example, it is a process with critical gases.
Avoidance of risks
With a hook-up solution, users circumvent the efforts and potential risks described here. The measuring arrangement is assembled at WIKA (based on the specified process parameters and the installation situation) from qualified individual parts and is tested for leaks. It is ready for installation along the way on delivery. If necessary, a measuring instrument can also be combined with several instrumentation valves and accessories (see illustration left).
Note
Detailed info on valves and protective devices can be found on the WIKA website.